  Tetraethylsilane      Revision number: 5    
  SAFETY DATA SHEET

Section 1. IDENTIFICATION
  Product name:        Tetraethylsilane    
    
  Revision number:        5    

Section 2. HAZARDS IDENTIFICATION
  GHS classification
  PHYSICAL HAZARDS
    Category 3
  Flammable liquids
  HEALTH HAZARDS        Not classified    
    Not classified
  ENVIRONMENTAL HAZARDS
  GHS label elements, including precautionary statements
  Pictograms or hazard symbols
  Signal word        Warning    
  Hazard statements        Flammable liquid and vapour    
  Precautionary statements:
  [Prevention]        Keep away from heat/sparks/open flames/hot surfaces. - No smoking.    
    Keep container tightly closed.
    Use explosion-proof electrical/ventilating/lighting equipment. Take precautionary
    measures against ignition by the static discharge and the spark.
    Wear protective gloves/eye protection/face protection.
  [Response]        IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse    
    skin with water/shower.
  [Storage]        Store in a well-ventilated place. Keep cool.    
    Dispose of contents/container through a waste management company authorized by
  [Disposal]
    the local government.

Section 3. COMPOSITION/INFORMATION ON INGREDIENTS
  Substance/mixture:        Substance    
  Components:        Tetraethylsilane    
  Percent:        >97.0%(GC)    
  CAS Number:        631-36-7    
  Chemical Formula:        C8H20Si    

Section 4. FIRST AID MEASURES
  Inhalation:        Remove victim to fresh air and keep at rest in a position comfortable for breathing.    
    Get medical advice/attention if you feel unwell.
  Tetraethylsilane

Section 4. FIRST AID MEASURES
  Skin contact:        Remove/Take off immediately all contaminated clothing. Rinse skin with    
    water/shower. If skin irritation or rash occurs: Get medical advice/attention.
  Eye contact:        Rinse cautiously with water for several minutes. Remove contact lenses, if present    
    and easy to do. Continue rinsing. If eye irritation persists: Get medical
    advice/attention.
  Ingestion:        Get medical advice/attention if you feel unwell. Rinse mouth.    
    A rescuer should wear personal protective equipment, such as rubber gloves and air-
  Protection of first-aiders:
    tight goggles.

Section 5. FIRE-FIGHTING MEASURES
  Suitable extinguishing        Dry chemical, foam, carbon dioxide.    
  media:
  Unsuitable extinguishing Water (It may scatter and spread fire.)
  media:
  Specific hazards arising Take care as it may decompose upon combustion or in high temperatures to
  from the chemical:        generate poisonous fume.    
  Precautions for firefighters: Fire-extinguishing work is done from the windward and the suitable fire-extinguishing
    method according to the surrounding situation is used. Uninvolved persons should
    evacuate to a safe place. In case of fire in the surroundings: Keep containers cool by
    spraying with water. Eliminate all ignition sources if safe to do so.
  Special protective        When extinguishing fire, be sure to wear personal protective equipment.    
  equipment for firefighters:

Section 6. ACCIDENTAL RELEASE MEASURES
  Personal precautions,        Use personal protective equipment. Keep people away from and upwind of spill/leak.    
  protective equipment and Ensure adequate ventilation. Entry to non-involved personnel should be controlled
  emergency procedures: around the leakage area by roping off, etc.
  Environmental precautions: Prevent product from entering drains.
  Methods and materials for Absorb spilled material in dry sand or inert absorbent before recovering it into an
  containment and cleaning airtight container. In case of large amount of spillage, contain a spill by bunding.
  up: Adhered or collected material should be promptly disposed of, in accordance with
    appropriate laws and regulations.
  Prevention of secondary Remove all sources of ignition. Fire-extinguishing devices should be prepared in
  hazards:        case of a fire. Use spark-proof tools and explosion-proof equipment.    

Section 7. HANDLING AND STORAGE
  Precautions for safe handling
  Technical measures:        Handling is performed in a well ventilated place. Wear suitable protective equipment.    
    Prevent generation of vapour or mist. Keep away from heat/sparks/open flame/hot
    surfaces. -No smoking. Take measures to prevent the build up of electrostatic
    charge. Use explosion-proof equipment. Wash hands and face thoroughly after
    handling.
    Use a closed system if possible. Use a ventilation, local exhaust if vapour or aerosol
    will be generated.
  Advice on safe handling: Avoid contact with skin, eyes and clothing.
  Conditions for safe storage, including any
  incompatibilities
  Storage conditions:        Keep container tightly closed. Store in a cool, dark and well-ventilated place.    
    Store under inert gas.
    Protect from moisture.
    Store away from incompatible materials such as oxidizing agents.
    Moisture-sensitive
    Comply with laws.
  Packaging material:

Section 8. EXPOSURE CONTROLS / PERSONAL PROTECTION
  Engineering controls:        Install a closed system or local exhaust. Also install safety shower and eye bath.    
  Tetraethylsilane

Section 8. EXPOSURE CONTROLS / PERSONAL PROTECTION
  Personal protective equipment
  Respiratory protection: Vapor respirator. Follow local and national regulations.
  Hand protection:        Protective gloves.    
    Safety glasses. A face-shield, if the situation requires.
  Eye protection:
  Skin and body protection: Protective clothing. Protective boots, if the situation requires.

Section 9. PHYSICAL AND CHEMICAL PROPERTIES
  Physical state (20°C):        Liquid    
    Clear
  Form:
  Colour:        Colorless - Almost colorless    
    No data available
  Odour:
  pH: No data available
  Melting point/freezing point:No data available
  Boiling point/range:        155°C    
    25°C
  Flash point:
  Flammability or explosive
  limits:
  Lower:        No data available    
  Upper:        No data available    
  Relative density:        0.77    
  Solubility(ies):
  [Water]        No data available    
    No data available
  [Other solvents]

Section 10. STABILITY AND REACTIVITY
  Chemical stability:        Stable under proper conditions.    
  Possibility of hazardous No special reactivity has been reported.
  reactions:
  Conditions to avoid:        Spark, Open flame, Static discharge    
  Incompatible materials: Oxidizing agents
  Hazardous decomposition Carbon monoxide, Carbon dioxide, Silicon oxides
  products:

Section 11. TOXICOLOGICAL INFORMATION
    ihl-mus LC:>1770 mg/m3/10M
  Acute Toxicity:
  Skin corrosion/irritation: No data available
  Serious eye        No data available    
  damage/irritation:
  Germ cell mutagenicity: No data available
  Carcinogenicity:
  IARC =        No data available    
    No data available
  NTP =
  Reproductive toxicity:        No data available    
    VV5500000
  RTECS Number:

Section 12. ECOLOGICAL INFORMATION
  Ecotoxicity:
  Fish:        No data available    
  Crustacea:        No data available    
  Algae:        No data available    
  Persistence / degradability: No data available
  Bioaccumulative        No data available    
  potential(BCF):
  Mobility in soil
  Log Pow:        No data available    
  Soil adsorption (Koc):        No data available    
  Tetraethylsilane

Section 12. ECOLOGICAL INFORMATION
  Henry's Law        No data available    
  constant(PaM3/mol):

Section 13. DISPOSAL CONSIDERATIONS
    Recycle to process, if possible. Consult your local regional authorities. You may be able to burn in a chemical
    incinerator equipped with an afterburner and scrubber system. Observe all federal, state and local regulations when
    disposing of the substance.

Section 14. TRANSPORT INFORMATION
  Hazards Class:        3: Flammable liquid.    
    1993
  UN-No:
  Proper shipping name:        Flammable liquid, n.o.s.    
  Packing group:        III    

Section 15. REGULATORY INFORMATION
  Safe management ordinance of dangerous chemical product (State Council announces on January 26, 2002
  and revised on February 16,2011): Safe use and production, the storage of a dangerous chemical, transport,
    loading and unloading were prescribed.


SECTION 16 - ADDITIONAL INFORMATION
N/A

Home   |   Announcement   |   Partners   |   Business Cooperation   |   Suppliers   |   Products    |   About Us   |   Contact Us   |   Privacy Policy   |   Terms & Conditions   |   Legal Statement

Copyright © 2013-2016 MOLBASE All Rights Reserved ICP Shanghai 14014220